Assessing the Existing Electrical Infrastructure for Your Office Lighting

YOUR FIRST CALL LONDON ELECTRICIANS
CALL US TODAY WE CAN HELP!

020 7060 0999

Is Your Current Office Electrical Wiring Up to the Job

Before new office lighting or commercial lighting can be installed, or an existing system upgraded, a thorough assessment of the current electrical infrastructure supplying the luminaires is essential. This investigation determines the suitability and safety of the existing wiring, how power is currently delivered to fittings, and what modifications or upgrades might be necessary to support your new lighting design safely and in compliance with BS7671 (the Electrical Regulations). For a comprehensive understanding of your current installation’s compliance, an Electrical Installation Condition Report (EICR) can be invaluable before embarking on major lighting alterations.

Key Aspects of the Infrastructure Assessment:

  • Identifying the Current Power Supply Method to Light Fittings: Understanding how existing light fittings are powered is crucial. Common methods found in office lighting and commercial lighting installations include:
    • Plug-in Systems (Lighting Roses/Connectors): Systems like ‘Click’ roses or Marshall Tufflex (MT) connection boxes provide a modular way to connect light fittings, often found above suspended ceilings.
    • Conduit Systems with Flexible Cables: Fixed conduit may protect wiring, with flexible cables running to individual fittings.
    • Direct Wiring to Junction Boxes: Fittings might be wired via traditional junction boxes. It’s important to note that to comply with BS7671 (the Electrical Regulations), these junction boxes must remain accessible for inspection and maintenance. This can sometimes be challenging to achieve, particularly where MF (Metal-Framed) plasterboard ceilings are installed, as access may be sealed.
  • Identifying Non-Compliant or Unsafe Wiring Practices: A common and serious issue encountered is finding cables merely ‘slung’ across suspended ceiling grids and resting directly on top of ceiling tiles. This practice is not compliant with BS7671 (the Electrical Regulations) and presents multiple hazards:
    • Lack of Mechanical Protection: Cables are vulnerable to damage, especially where partition walls are installed, as the tops of these walls are often screwed directly to or through the ceiling grid. Such damage can potentially cause the metal frame of the wall, and even the ceiling grid itself, to become live if a cable is pierced, creating a serious electric shock risk.
    • Overheating Risk: Cables laid on insulation or tiles can overheat if not correctly rated and installed for such an environment.
    • Difficult and Unsafe Maintenance: When cables are installed in this haphazard way, it makes it very difficult and potentially unsafe to remove ceiling tiles for routine inspection, for installing other new services (like data cabling or air conditioning components), or for accessing the lighting wiring itself.
    • Excessive Weight on Suspended Ceilings: Suspended ceilings are not designed to bear significant additional weight from services laid directly upon them. There have been incidents where such ceilings have collapsed due to the excessive weight of unsupported cables, ducting, or other items, posing a severe hazard.
  • Verifying Circuit Loadings and Protection: It’s essential to check that the existing lighting circuits are not already overloaded and can safely handle the electrical load of any new or additional fittings. The protective devices (fuses or circuit breakers) at the distribution board must be correctly rated for the circuit wiring and the anticipated load.
  • Condition of Existing Accessories: Switches, connectors, and any existing control gear related to the lighting circuits will also be inspected for their condition and suitability for continued use or integration with a new system.

A comprehensive assessment of the existing electrical infrastructure for your lighting installation ensures that your new system is built on a safe and compliant foundation. Any identified deficiencies, such as non-compliant “slung” cables, inaccessible junction boxes, or overloaded circuits, must be rectified as part of a professional lighting upgrade to guarantee the safety and reliability of your Central London office or commercial space.

 

Follow the link to our next page >>>> Emergency Lighting Design & Integration in Offices & Commercial Spaces

Is Your Current Office Electrical Wiring Up to the Job

Before new office lighting or commercial lighting can be installed, or an existing system upgraded, a thorough assessment of the current electrical infrastructure supplying the luminaires is essential. This investigation determines the suitability and safety of the existing wiring, how power is currently delivered to fittings, and what modifications or upgrades might be necessary to support your new lighting design safely and in compliance with BS7671 (the Electrical Regulations). For a comprehensive understanding of your current installation’s compliance, an Electrical Installation Condition Report (EICR) can be invaluable before embarking on major lighting alterations.

Key Aspects of the Infrastructure Assessment:

  • Identifying the Current Power Supply Method to Light Fittings: Understanding how existing light fittings are powered is crucial. Common methods found in office lighting and commercial lighting installations include:
    • Plug-in Systems (Lighting Roses/Connectors): Systems like ‘Click’ roses or Marshall Tufflex (MT) connection boxes provide a modular way to connect light fittings, often found above suspended ceilings.
    • Conduit Systems with Flexible Cables: Fixed conduit may protect wiring, with flexible cables running to individual fittings.
    • Direct Wiring to Junction Boxes: Fittings might be wired via traditional junction boxes. It’s important to note that to comply with BS7671 (the Electrical Regulations), these junction boxes must remain accessible for inspection and maintenance. This can sometimes be challenging to achieve, particularly where MF (Metal-Framed) plasterboard ceilings are installed, as access may be sealed.
  • Identifying Non-Compliant or Unsafe Wiring Practices: A common and serious issue encountered is finding cables merely ‘slung’ across suspended ceiling grids and resting directly on top of ceiling tiles. This practice is not compliant with BS7671 (the Electrical Regulations) and presents multiple hazards:
    • Lack of Mechanical Protection: Cables are vulnerable to damage, especially where partition walls are installed, as the tops of these walls are often screwed directly to or through the ceiling grid. Such damage can potentially cause the metal frame of the wall, and even the ceiling grid itself, to become live if a cable is pierced, creating a serious electric shock risk.
    • Overheating Risk: Cables laid on insulation or tiles can overheat if not correctly rated and installed for such an environment.
    • Difficult and Unsafe Maintenance: When cables are installed in this haphazard way, it makes it very difficult and potentially unsafe to remove ceiling tiles for routine inspection, for installing other new services (like data cabling or air conditioning components), or for accessing the lighting wiring itself.
    • Excessive Weight on Suspended Ceilings: Suspended ceilings are not designed to bear significant additional weight from services laid directly upon them. There have been incidents where such ceilings have collapsed due to the excessive weight of unsupported cables, ducting, or other items, posing a severe hazard.
  • Verifying Circuit Loadings and Protection: It’s essential to check that the existing lighting circuits are not already overloaded and can safely handle the electrical load of any new or additional fittings. The protective devices (fuses or circuit breakers) at the distribution board must be correctly rated for the circuit wiring and the anticipated load.
  • Condition of Existing Accessories: Switches, connectors, and any existing control gear related to the lighting circuits will also be inspected for their condition and suitability for continued use or integration with a new system.

A comprehensive assessment of the existing electrical infrastructure for your lighting installation ensures that your new system is built on a safe and compliant foundation. Any identified deficiencies, such as non-compliant “slung” cables, inaccessible junction boxes, or overloaded circuits, must be rectified as part of a professional lighting upgrade to guarantee the safety and reliability of your Central London office or commercial space.

 

Follow the link to our next page >>>> Emergency Lighting Design & Integration in Offices & Commercial Spaces